免费国产综合视频在线看_国产大片91精品免费看3_国产成人综合95精品视频免费_国产精品亚洲片在线观看不卡_国产在线观看麻豆91精品免费_99re6这里只有精品_久久只有这才是精品99_国产免费久久精品99_亚洲精品欧美综合四区

Ocean Acidification Measurement System Scheme
Changes in carbon dioxide (CO2), the major end product of organic carbon degradation in nearly all aquatic environments, are often a measure of net ecosystem metabolism. Therefore, in aquatic biogeochemical studies, the parameters that define the carbon dioxide system need to be measured. Carbon dioxide is also the most important greenhouse gas on Earth. Its air-water interface exchange flux is one of the most important issues in global change research and is often a measure of net ecosystem production/metabolism in aquatic systems.
方案構(gòu)成

The ocean acidification measurement system is mainly composed of a time series water sampler, a dissolved inorganic carbon analyzer, a total alkalinity titrator, a spectrophotometric seawater pH analyzer, and a navigational carbon dioxide partial pressure system, which are carried on the shipboard laboratory. It can also be equipped with Ferrybox ecological monitoring station, UCTD walking profile measurement system, WaMos II wave monitoring system and other equipment. Water samples are collected using a time-series water sampler (equipped with CTD sensors) and then entered into a marine chemistry laboratory to simultaneously measure dissolved inorganic carbon, total alkalinity, pH, and air-sea carbon dioxide fluxes in seawater.

方案特點
  • The time series water sampler can collect water samples in the deep sea. The instrument can analyze the dissolved inorganic carbon concentration range of 0.2-20mM, pH measurement range of 0-14, carbon dioxide measurement range of 0-20000ppm

    Wide range of analysis

    The time series water sampler can collect water samples in the deep sea. The instrument can analyze the dissolved inorganic carbon concentration range of 0.2-20mM, pH measurement range of 0-14, carbon dioxide measurement range of 0-20000ppm
  • The UCTD walking profile measurement system used is extremely accurate (temperature ±0.004°C, salinity 0.02-0.05 psu, depth 1 dbar), and the analytical accuracy of laboratory instruments is as high as 0.1%

    high accuracy

    The UCTD walking profile measurement system used is extremely accurate (temperature ±0.004°C, salinity 0.02-0.05 psu, depth 1 dbar), and the analytical accuracy of laboratory instruments is as high as 0.1%
  • Applicable to all kinds of aquatic environments, the sample volume required by laboratory instruments is very small ≤ 50mL

    Strong applicability

    Applicable to all kinds of aquatic environments, the sample volume required by laboratory instruments is very small ≤ 50mL
  • The design and implementation of the project are carried out in accordance with the requirements of standardization and standardization. The hardware configuration and software adopts the international standardization technology to avoid the obstacles of system interconnection; fully considering the compatibility of the system, each sub-system can support subsequent upgrades and expansions. Development laboratory analysis Basically, one parameter can be measured within 5 minutes, and the speed of navigation analysis is faster, which can reach 1 minute.

    Faster analysis rate

    The design and implementation of the project are carried out in accordance with the requirements of standardization and standardization. The hardware configuration and software adopts the international standardization technology to avoid the obstacles of system interconnection; fully considering the compatibility of the system, each sub-system can support subsequent upgrades and expansions. Development laboratory analysis Basically, one parameter can be measured within 5 minutes, and the speed of navigation analysis is faster, which can reach 1 minute.
  • Basically, one of the laboratory analysis parameters can be measured within 5 minutes, and the walking analysis rate is faster, up to 1 minute

    High stability

    Basically, one of the laboratory analysis parameters can be measured within 5 minutes, and the walking analysis rate is faster, up to 1 minute
  • The instrument can realize automatic measurement, so as to realize unattended measurement and reduce labor costs

    high degree of automation

    The instrument can realize automatic measurement, so as to realize unattended measurement and reduce labor costs
應(yīng)用領(lǐng)域

The ocean acidification measurement system solution can be applied to a variety of aquatic environments including seawater, offshore bodies, sediment pore water, and time-series culture fluid samples.

典型案例
The Institute of Oceanography, Chinese Academy of Sciences, the South China Sea Institute of Oceanography, the First, Second, and Third Oceanographic Research Institutes of the Ministry of Natural Resources, the National Marine Environmental Monitoring Center and other units have successfully used this ocean acidification measurement system scheme to obtain a large number of ocean acidification parameters. important data.
淺海
淺海
淺海 官方公眾號
聯(lián)系我們
淺海浙江省杭州市濱江區(qū)和瑞科技園T1-11F
淺海淺海
聯(lián)系電話
86-0571-81956003
淺海淺海
官方微信
淺海
淺海淺海
在線留言
淺海